Azek Deck EN Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
Page 11
Stair Code Compliance
In order to meet the AC174 Requirement for stair loading, follow one of the methods below:
3
2
1
AZEK 1x6 Decking
attached to
Stringers using (2)
#7 x 2 1/4” Screws
Attach 2 x 4 treated pine
centered under treads using
pneumatic framing nailer.
Nail positions as shown.
3 1/4” x .0131
roundrive framing
nail in locations
shown using
pneumatic nailer.
AZEK Deck Board
attached to Stringers
using 2 Screws/
Stringers.
Angle
Brackets
AZEK Deck Board
(Typical)
AZEK
Deck
Tread
Treated Pine
Stair Stringer
9.00”
Maximum
26.00” Minimum
7.50”
4.25”
1.875”
49.5”
36”
24.0”
17.25”
Installing Stairs
• Stairs should be constructed per local code requirements.
• Use XLM Riser Board or a AZEK ripped Rim Joist Covers for riser installation.
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16

Comentarios a estos manuales

Sin comentarios